ai.sparkquote/nec-calculators
up checked
Unclaimed · Unverified
Agent searches it appeared in, last 30 days: 0. Run this server? Claim the listing: verified label, uptime alerts and analytics.
Publisher-provided title
SparkQuote NEC calculators
Publisher-provided description
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
Summary by lookupd
Runs NEC 2023 electrical calculations such as wire sizing, conduit and box fill, voltage drop, service load, and bid pricing.
Install
Claude Code, remote (streamable-http)
claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp
Codex, remote (streamable-http)
codex mcp add nec-calculators --url https://sparkquote.ai/mcp
Cursor, remote (streamable-http) → .cursor/mcp.json
{
"mcpServers": {
"nec-calculators": {
"url": "https://sparkquote.ai/mcp"
}
}
}Other clients: docs. Or tell your agent: Set up lookupd for me: read https://lookupd.com/agent.md and follow it.
Tools (10 tools)
Publisher-provided text
wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over thvoltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conducload_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or coohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), befor
Details
- Version: 1.0.1
- Transports: streamable-http
- Uptime (7 days): 100%
- Median latency: 547 ms
- First indexed:
- Last seen in registry:
- Website: https://sparkquote.ai/tools/mcp-server
Badge for your README
Shows this live status and links here; updates hourly.
[](https://lookupd.com/servers/ai.sparkquote/nec-calculators)
- 62033 servers
- Last crawl: 2026-11-11T15:38:39.561Z
- API base:
https://api.lookupd.com - MCP URL:
https://api.lookupd.com/mcp